Network Adapter |
Total Ethernet |
16 |
10/100 Mbit/s |
16 |
Type 10/100 Mbit/s |
2xST, Multi-mode, 14xRJ-45 |
Type Ethernet |
10BASE-T, 100BASE-F, 100BASE-T |
Network Technology |
Managed |
No, Layer 2 |
IEEE Standard |
IEEE 802.1P for Class of Service, IEEE 802.3 for 10BaseT, IEEE 802.3u for 100BaseT(X) and 100BaseFX, IEEE 802.3x for Flow Control |
Switch Properties |
Packet Buffer Size |
2 MBit |
MAC Table Size |
8000 |
Technologies and Functions |
Supported technologies |
QoS |
Supported functions |
Broadcast Storm Protection, Automatic power failure notification, Automatic port failure notification |
Digital Output |
Total channels of digital output |
1 |
Type |
Signal Relay |
Contact rating of relay (Form A) |
1A@24V DC |
Cooling |
Type |
Fanless |
LED / Controls |
LED |
FAULT LED, 10/100M LED, PWR1, PWR2 |
Setup of Operation Mode |
By Switches |
System Power Input |
Input Voltage DC |
9.6~60 V |
Power Consumption |
4.9 W |
Current |
0.204 A |
Power Supply Reserve input Voltage DC |
9.6~60 V |
Power Consumption Reserve |
4.9 W |
Current Reserve |
0.204 A |
Power Input Protection |
Fuze, Reverse Polarity |
Operating Conditions |
Temperature |
-40~75 °C |
Humidity |
5~95 % |
MTBF |
2070826 |
Storage Conditions |
Temperature Range |
-40~85 °C |
Construction |
Construction Chassis |
Metal Chassis |
Mounting Configuration |
Wall, DIN-Rail mount |
Protection Level of Chassis |
IP30 |
Dimensions and weight |
Width |
58 mm |
Height |
135 mm |
Depth |
95 mm |
Standards and Certifications |
Vibration And Shock |
IEC 60068-2-6, IEC 60068-2-27 |
Freefall |
IEC 60068-2-32 |
Safety |
UL 61010-2-201, EN 62368 |
EMS |
IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, EN 55032, EN 55035 |
EMI |
FCC Part 15 Subpart B Class A, CISPR 32 |
Rolling Stock |
EN 50121-4 |