Interfaces |
COM Total |
2 |
RS-232 |
1 |
Maximum Transfer Rate RS-232 |
230400 Bit/s |
RS-232 with Isolation |
2500 V |
RS-422/485 |
1 |
RS-422/485 with Isolation |
2500 V |
COM Connector |
1xDB9, Terminal Block |
Network Adapter |
10/100 Mbit/s |
2 |
Type 10/100 Mbit/s |
2xSC |
Digital Output |
Total channels of digital output |
1 |
Type |
Electromagnitic relay |
Relay (Form C) |
1 |
Cooling |
Type |
Fanless |
LED / Controls |
LED |
Module Fail, TX LED, RX LED, Master LED, PWR1, PWR2 |
Setup of Operation Mode |
By Switches |
Connectors / Cables |
Connectors |
DC input (terminal block) |
System Power Input |
Input Voltage DC |
9.6~58 V |
Power Consumption |
6 W |
Power Supply Reserve input Voltage DC |
9.6~58 V |
Power Input Protection |
Reverse Polarity |
Operating Conditions |
Temperature |
-10~60 °C |
Humidity |
5~95 % |
MTBF |
687418 |
Storage Conditions |
Temperature Range |
-40~85 °C |
Construction |
Construction Chassis |
Metal Chassis |
Mounting Configuration |
Wall, DIN-Rail mount |
Protection Level of Chassis |
IP30 |
Dimensions and weight |
Width |
38.6 mm |
Height |
142.1 mm |
Depth |
106 mm |
Standards and Certifications |
Certifications |
CE |
Vibration And Shock |
IEC 60068-2-6, IEC 60068-2-27 |
Freefall |
IEC 60068-2-32 |
Safety |
UL 60950-1 |
EMS |
EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-6-2, EN 61000-6-4 |
EMI |
EN 55022 Class A |