Skip to content

M-7046

by ICP DAS
Price on request
15-channel Isolated Digital Input Module using the DCON or Modbus Protocol (Gray Cover) (RoHS)

Interfaces

RS-485 1
Maximum Transfer Rate RS-485 115200 Bit/s

Industrial Protocols

Modbus RTU Slave
DCON Slave

Digital Input

Total channels of digital input 15
Type Dry contact, Wet contact
Sink/Source Dry: Source, Wet: Sink/Source
On voltage level for wet contact 3.5~50 V
Off voltage level for wet contact 0~1 V
Counter 100Hz, 16 bit
Isolation of Digital Input 5000 V

Connectors / Cables

Connectors Screw Terminal

Watchdog

Hardware Yes
Programmable Yes

System Power Input

Input Voltage DC 10~30 V
Power Consumption 0.2 W

Operating Conditions

Temperature -25~75 °C
Humidity 10~95 %

Storage Conditions

Temperature Range -40~85 °C

Construction

Construction Chassis Plastic Chassis
Mounting Configuration Wall, DIN-Rail mount

Dimensions and weight

Width 72 mm
Height 123 mm
Depth 35 mm

Standards and Certifications

EMS IEC 61000-4-2, IEC 61000-4-4, IEC 61000-4-5